Electrical

#Electrical

5 articles
Hardware / IoT
Drawing SVG Electrical Panels You Can Measure on Paper
Hardware

Drawing SVG Electrical Panels You Can Measure on Paper

The electrical panel drawings I generated from HTML looked good, but the technician said the proportions were wrong. I rebuilt the whole sheet, anchored it to actual catalog dimensions, wrote the viewBox directly in millimeters, and added a scale bar so the technician could use a ruler to verify that the drawing in hand really was at 1:10.

#drafting#cad#electrical#printing
9 min read·24 Oct
No kWh Meter? Estimate Daily Electricity Costs from Current
Hardware

No kWh Meter? Estimate Daily Electricity Costs from Current

Notes on converting CT current readings into energy usage and daily time-of-use electricity costs, from the three-phase power formula and the sampling interval built into it, through skipping outages and separating peak from off-peak with epoch arithmetic, to a daily summary table that made the web page seven times faster.

#energy#power-meter#electrical#modbus
10 min read·15 Oct
Shared Neutrals Across Transformers: Why Phase Balancing Is Not Enough
Hardware

Shared Neutrals Across Transformers: Why Phase Balancing Is Not Enough

A case involving two transformers with interconnected neutrals and houses tapped into one side's main feeder, leaving phase A 30-40 A higher even on days off, plus a meter-reading trap that can suggest a 200 A difference if the CT ratio is not verified first, and a repair sequence that must be followed in order.

#hardware#electrical#power#engineering
9 min read·30 Sep
Sizing Main Cables and Breakers by Installation Method
Hardware

Sizing Main Cables and Breakers by Installation Method

Notes on choosing the main cable and breaker for a new 253 A feeder, why the same size CV cable can carry 227 A or 364 A depending on how it is installed, and the option of downsizing to 95 and compensating with operating rules, at the cost of the main breaker tripping if anyone breaks those rules.

#hardware#electrical#power#engineering
10 min read·29 Sep
Diagnosing Feeder Overload from Melted Insulation and Duty Cycles
Hardware

Diagnosing Feeder Overload from Melted Insulation and Duty Cycles

My investigation of a 95 mm² main cable with insulation melting at scattered points even though the system seemed to work normally, from the nameplates of 6 washers and dryers totaling 234.7 kW to a minute-by-minute current model explaining why a 482 A load on a cable rated for 180 A had not caused a visible system failure.

#hardware#electrical#power#engineering
10 min read·28 Sep